Developing and Analytical Application of Modified Electrode for the Electrochemical Determination of Rafoxanide Veterinary Drug


Abstract views: 18 / PDF downloads: 8

Authors

  • Ersin Demir
  • Nida Aydogdu Ozdogan writing
  • Cengiz Sarikurkcu
  • Muhammet Burak Acikgul
  • Hulya Silah

DOI:

https://doi.org/10.5281/zenodo.14568602

Keywords:

Rafoxanide, Detection, Electroanalytical, Modified electrode, TiO2 nanoparticles

Abstract

Electrochemical behavior and analytical applications of rafoxanide drug substance, which is used as an anthelmintic and is a salicylanilide family, was investigated by the cyclic voltammetry (CV), differential pulse stripping voltammetry (DPSV), and square wave stripping voltammetry (SWSV) on modified the titanium dioxide nanoparticles/multi-walled carbon paste electrode (TiO2 NPs/MWCNTPE). The rafoxanide showed a well-defined anodic signal, has an irreversible electrode reaction, at approximately 0.45 V in the optimum pH 6.0 Britton Robinson (BR) buffer solutions. Some parameters of stripping modules such as supporting electrolyte, pH, frequency, deposition time, pulse time and pulse amplitude, etc. were optimized to develop the most sensitive electroanalytical method. Furthermore, the calibration graphs were created using the standard addition technique with SWSV and DPSV on the optimum condition. It has a linear working range of 2.0–16.0 mg/L with SWSV and 2.5–14 mg/L with DPSV for the determination of rafoxanide in pH 6.0 BR buffer solution on the TiO2 NPs/MWCNTPE. The limit of determination (LOD) by SWSV and DPSV, which are the most important validation parameter, was found to be 0.054 and 0.072 mg/L, respectively. To investigate the selectivity of the method, analysis of 5 mg/L rafoxanide was carried out on TiO2 NPs/MWCNTPE with SWSV in the presence of various heavy metals and some organic substances. The interference agents had no significant effect on the determination of rafoxanide (less than 10% within the tolerance range). Finally, the rafoxanide drug was successfully evaluated in tap water samples by the proposed SWSV without any pretreatment with a high percent recovery. Subsequently, a fast, inexpensive, reliable, portable, environmentally friendly, selective and sensitive new electroanalytical method has been improved to deduce rafoxanide in real samples.

References

Saad AS, Hamdy AM, Salama FM, Abdelkawy M. Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products. J Chromatogr Sci [Internet]. 2016 Oct;54(9):1661–9.

Sweetman SC, Blake PS, McGlashan JM. Martindale: The Complete Drug Reference 35th ed. London: Pharmaceutical Press; 2007.

Council of the European Union. EU Commission Regulation No. 2377/90. In Off. J. Eur. Commun; 1990. p. 1–8.

Yeung H, Lee W, Wong Y. Screening of closantel and rafoxanide in animal muscles by HPLC with fluorescence detection and confirmation using MS. J Sep Sci [Internet]. 2010 Feb;33(2):206–11.

Benchaoui HA, McKellar QA. Determination of rafoxanide and closantel in ovine plasma by high performance liquid chromatography. Biomed Chromatogr [Internet]. 1993 Jul;7(4):181–3.

Talley CP, Trenner NR, Downing G V., VandenHeuvel WJA. Gas chromatographic determination of rafoxanide [3’-chloro-4’-(4-chlorophenoxy)-3,5-diiodosalicylanilide] in plasma by electron capture detection of its trimethylsilyl derivative. Anal Chem [Internet]. 1971 Aug 1;43(11):1379–82.

Fink DW. Spectrophotometric quantification of the salicylanilide anthelmintic rafoxanide based on the charge-transfer absorbance of its iron(III) complex. Anal Chim Acta [Internet]. 1981 Nov;131:281–5.

Horning EC, Maddock KC, Anthony K V., VandenHeuvel WJA. Quantitative Aspects of Gas Chromatographic Separations in Biological Studies. Anal Chem [Internet]. 1963

Blanchflower WJ, Kennedy DG, Taylor SM. Determination of Rafoxanide in Plasma Using High Performance Liquid Chromatography (HPLC) and in Tissue Using HPLC-Thermospray Mass Spectrometry. J Liq Chromatogr [Internet]. 1990 Apr;13(8):1595–609.

Saad AS, Attia AK, Alaraki MS, Elzanfaly ES. Comparative study on the selectivity of various spectrophotometric techniques for the determination of binary mixture of fenbendazole and rafoxanide. Spectrochim Acta Part A Mol Biomol Spectrosc [Internet]. 2015 Nov;150:682–90.

Demir E, Göktug Ö, İnam R, Doyduk D. Development and characterization of iron (III) phthalocyanine modified carbon nanotube paste electrodes and application for determination of fluometuron herbicide as an electrochemical sensor. J Electroanal Chem [Internet]. 2021 Aug;895:115389.

Inam O, Demir E, Uslu B. Voltammetric Pathways for the Analysis of Ophthalmic Drugs. Curr Pharm Anal [Internet]. 2020 Apr 27;16(4):367–91.

Isildak I, Attar A, Demir E, Kemer B, Aboul-Enein HY. A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore. Curr Anal Chem [Internet]. 2018 Jan 8;14(1).

Karimi F, Demir E, Aydogdu N, Shojaei M, Taher MA, Asrami PN, et al. Advancement in electrochemical strategies for quantification of Brown HT and Carmoisine (Acid Red 14) From Azo Dyestuff class. Food Chem Toxicol [Internet]. 2022 Jul;165:113075.

Silah H, Erkmen C, Demir E, Uslu B. Modified indium tin oxide electrodes: Electrochemical applications in pharmaceutical, biological, environmental and food analysis. TrAC Trends Anal Chem [Internet]. 2021 Aug;141:116289.

Sarakhman O, Švorc Ľ. A Review on Recent Advances in the Applications of Boron-Doped Diamond Electrochemical Sensors in Food Analysis. Crit Rev Anal Chem [Internet]. 2022 May 19;52(4):791–813.

Umapathi R, Ghoreishian SM, Sonwal S, Rani GM, Huh YS. Portable electrochemical sensing methodologies for on-site detection of pesticide residues in fruits and vegetables. Coord Chem Rev [Internet]. 2022 Feb;453:214305.

Radi A-E, El-samboskany H. Anodic Adsorptive Stripping Voltammetric Determination of Rafoxanide on Glassy Carbon Electrode. Comb Chem High Throughput Screen [Internet]. 2020 Dec 28;23(10):1002–9.

Laviron E, Roullier L, Degrand C. A multilayer model for the study of space distributed redox modified electrodes. J Electroanal Chem Interfacial Electrochem [Internet]. 1980 Sep;112(1):11–23.

Gustavo González A, Ángeles Herrador M. A practical guide to analytical method validation, including measurement uncertainty and accuracy profiles. TrAC Trends Anal Chem [Internet]. 2007 Mar;26(3):227–38.

Downloads

Published

2024-12-30

How to Cite

Demir, E., Aydogdu Ozdogan, N., Sarikurkcu, C., Acikgul, M. B., & Silah, H. (2024). Developing and Analytical Application of Modified Electrode for the Electrochemical Determination of Rafoxanide Veterinary Drug. International Bulletin of Electrochemical Methodology, 1(1), 2024_1. https://doi.org/10.5281/zenodo.14568602

Issue

Section

Articles